Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
JACC Cardiovasc Imaging ; 17(4): 411-424, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38300202

RESUMO

BACKGROUND: Imaging with late gadolinium enhancement (LGE) magnetic resonance (MR) and 18F-fluorodeoxyglucose (18F-FDG) PET allows complementary assessment of myocardial injury and disease activity and has shown promise for improved characterization of active cardiac sarcoidosis (CS) based on the combined positive imaging outcome, MR(+)PET(+). OBJECTIVES: This study aims to evaluate qualitative and quantitative assessments of hybrid MR/PET imaging in CS and to evaluate its association with cardiac-related outcomes. METHODS: A total of 148 patients with suspected CS underwent hybrid MR/PET imaging. Patients were classified based on the presence/absence of LGE (MR+/MR-), presence/absence of 18F-FDG (PET+/PET-), and pattern of 18F-FDG uptake (focal/diffuse) into the following categories: MR(+)PET(+)FOCAL, MR(+)PET(+)DIFFUSE, MR(+)PET(-), MR(-)PET(+)FOCAL, MR(-)PET(+)DIFFUSE, MR(-)PET(-). Further analysis classified MR positivity based on %LGE exceeding 5.7% as MR(+/-)5.7%. Quantitative values of standard uptake value, target-to-background ratio, target-to-normal-myocardium ratio (TNMRmax), and T2 were measured. The primary clinical endpoint was met by the occurrence of cardiac arrest, ventricular tachycardia, or secondary prevention implantable cardioverter-defibrillator (ICD) before the end of the study. The secondary endpoint was met by any of the primary endpoint criteria plus heart failure or heart block. MR/PET imaging results were compared between those meeting or not meeting the clinical endpoints. RESULTS: Patients designated MR(+)5.7%PET(+)FOCAL had increased odds of meeting the primary clinical endpoint compared to those with all other imaging classifications (unadjusted OR: 9.2 [95% CI: 3.0-28.7]; P = 0.0001), which was higher than the odds based on MR or PET alone. TNMRmax achieved an area under the receiver-operating characteristic curve of 0.90 for separating MR(+)PET(+)FOCAL from non-MR(+)PET(+)FOCAL, and 0.77 for separating those reaching the clinical endpoint from those not reaching the clinical endpoint. CONCLUSIONS: Hybrid MR/PET image-based classification of CS was statistically associated with clinical outcomes in CS. TNMRmax had modest sensitivity and specificity for quantifying the imaging-based classification MR(+)PET(+)FOCAL and was associated with outcomes. Use of combined MR and PET image-based classification may have use in prognostication and treatment management in CS.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Fluordesoxiglucose F18 , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Cardiomiopatias/complicações , Meios de Contraste , Compostos Radiofarmacêuticos , Valor Preditivo dos Testes , Gadolínio , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Miocardite/complicações , Espectroscopia de Ressonância Magnética , Sarcoidose/diagnóstico por imagem , Sarcoidose/terapia , Sarcoidose/complicações
2.
J Heart Lung Transplant ; 43(4): 529-538, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951322

RESUMO

BACKGROUND: Previous retrospective studies suggest a good diagnostic performance of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/computed tomography (CT) in left ventricular assist device (LVAD) infections. Our aim was to prospectively evaluate the role of PET/CT in the characterization and impact on clinical management of LVAD infections. METHODS: A total of 40 patients (aged 58 [53-62] years) with suspected LVAD infection and 5 controls (aged 69 [64-71] years) underwent 18F-FDG-PET/CT. Four LVAD components were evaluated: exit site and subcutaneous driveline (peripheral), pump pocket, and outflow graft. The location with maximal uptake was considered the presumed site of infection. Infection was confirmed by positive culture (exit site or blood) and/or surgical findings. RESULTS: Visual uptake was present in 40 patients (100%) in the infection group vs 4 (80%) control subjects. For each individual component, the presence of uptake was more frequent in the infection than in the control group. The location of maximal uptake was most frequently the pump pocket (48%) in the infection group and the peripheral components (75%) in the control group. Maximum standard uptake values (SUVmax) were higher in the infection than in the control group: SUVmax (average all components): 6.9 (5.1-8.5) vs 3.8 (3.7-4.3), p = 0.002; SUVmax (location of maximal uptake): 10.6 ± 4.0 vs 5.4 ± 1.9, p = 0.01. Pump pocket infections were more frequent in patients with bacteremia than without bacteremia (79% vs 31%, p = 0.011). Pseudomonas (32%) and methicillin-susceptible Staphylococcus aureus (29%) were the most frequent pathogens and were associated with pump pocket infections, while Staphylococcus epidermis (11%) was associated with peripheral infections. PET/CT affected the clinical management of 83% of patients with infection, resulting in surgical debridement (8%), pump exchange (13%), and upgrade in the transplant listing status (10%), leading to 8% of urgent transplants. CONCLUSIONS: 18F-FDG-PET/CT enables the diagnosis and characterization of the extent of LVAD infections, which can significantly affect the clinical management of these patients.


Assuntos
Bacteriemia , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Coração Auxiliar/efeitos adversos , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Bacteriemia/diagnóstico , Bacteriemia/etiologia
3.
J Vis Exp ; (199)2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37811943

RESUMO

The current standard for measuring coronary artery calcification to determine the extent of atherosclerosis is by calculating the Agatston score from computed tomography (CT). However, the Agatston score disregards pixel values less than 130 Hounsfield Units (HU) and calcium regions less than 1 mm2. Due to this thresholding, the score is not sensitive to small, weakly attenuating regions of calcium deposition and may not detect nascent micro-calcification. A recently proposed metric called the spatially weighted calcium score (SWCS) also utilizes CT but does not include a threshold for HU and does not require elevated signals in contiguous pixels. Thus, the SWCS is sensitive to weakly attenuating, smaller calcium deposits and may improve the measurement of coronary heart disease risk. Currently, the SWCS is underutilized owing to the added computational complexity. To promote translation of the SWCS into clinical research and reliable, repeatable computation of the score, the aim of this study was to develop a semi-automatic graphical tool that calculates both the SWCS and the Agatston score. The program requires gated cardiac CT scans with a calcium hydroxyapatite phantom in the field of view. The phantom allows for deriving a weighting function, from which each pixel's weight is adjusted, allowing for the mitigation of signal variations and variability between scans. With all three anatomical views visible simultaneously, the user traces the course of the four main coronary arteries by placing points or regions of interest. Features such as scroll-to-zoom, double-click to delete, and brightness/contrast adjustment, along with written guidance at every step, make the program user-friendly and easy to use. Once tracing the arteries is complete, the program generates reports, which include the scores and snapshots of any visible calcium. The SWCS may reveal the presence of subclinical disease, which may be used for early intervention and lifestyle changes.


Assuntos
Calcinose , Doença da Artéria Coronariana , Humanos , Cálcio , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reprodutibilidade dos Testes , Angiografia Coronária/métodos
4.
Diagnostics (Basel) ; 13(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37296722

RESUMO

BACKGROUND: The aim of this study is to explore the utility of cardiac magnetic resonance (CMR) imaging of radiomic features to distinguish active and inactive cardiac sarcoidosis (CS). METHODS: Subjects were classified into active cardiac sarcoidosis (CSactive) and inactive cardiac sarcoidosis (CSinactive) based on PET-CMR imaging. CSactive was classified as featuring patchy [18F]fluorodeoxyglucose ([18F]FDG) uptake on PET and presence of late gadolinium enhancement (LGE) on CMR, while CSinactive was classified as featuring no [18F]FDG uptake in the presence of LGE on CMR. Among those screened, thirty CSactive and thirty-one CSinactive patients met these criteria. A total of 94 radiomic features were subsequently extracted using PyRadiomics. The values of individual features were compared between CSactive and CSinactive using the Mann-Whitney U test. Subsequently, machine learning (ML) approaches were tested. ML was applied to two sub-sets of radiomic features (signatures A and B) that were selected by logistic regression and PCA, respectively. RESULTS: Univariate analysis of individual features showed no significant differences. Of all features, gray level co-occurrence matrix (GLCM) joint entropy had a good area under the curve (AUC) and accuracy with the smallest confidence interval, suggesting it may be a good target for further investigation. Some ML classifiers achieved reasonable discrimination between CSactive and CSinactive patients. With signature A, support vector machine and k-neighbors showed good performance with AUC (0.77 and 0.73) and accuracy (0.67 and 0.72), respectively. With signature B, decision tree demonstrated AUC and accuracy around 0.7; Conclusion: CMR radiomic analysis in CS provides promising results to distinguish patients with active and inactive disease.

5.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1709-1716, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227360

RESUMO

BACKGROUND: Sustained ventricular tachycardia and sudden cardiac death due to degenerative mitral valve prolapse (MVP) can occur in the absence of severe mitral regurgitation (MR). A significant percentage of patients with MVP-related sudden death do not have any evidence of replacement fibrosis, suggesting other unrecognized proarrhythmic factors may place these patients at risk. OBJECTIVES: This study aims to characterize myocardial fibrosis/inflammation and ventricular arrhythmia complexity in patients with MVP and only mild or moderate MR. METHODS: Prospective observational study of patients with MVP and only mild or moderate MR underwent ventricular arrhythmia characterization and hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI). Coregistered hybrid 18F-fluorodeoxyglucose (18F-FDG)-PET and MRI late gadolinium enhancement images were assessed and categorized. Recruitment occurred in the cardiac electrophysiology clinic. RESULTS: In 12 patients with degenerative MVP with only mild or moderate MR, of which a majority had complex ventricular ectopy (n = 10, 83%), focal (or focal-on-diffuse) uptake of 18F-FDG (PET-positive) was detected in 83% (n = 10) of patients. Three-quarters of the patients (n = 9, 75%) had FDG uptake that coexisted with areas of late gadolinium enhancement (PET/MRI-positive). Abnormal T1, T2 and extracellular volume (ECV) values were observed in 58% (n = 7), 25% (n = 3), and 16% (n = 2), respectively. CONCLUSIONS: Most patients with degenerative MVP, ventricular ectopy, and mild or moderate MR show myocardial inflammation that is concordant with myocardial scar. Further study is needed to determine whether these findings contribute to the observation that most MVP-related sudden deaths occur in patients with less than severe MR.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Complexos Ventriculares Prematuros , Humanos , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Meios de Contraste , Gadolínio , Fluordesoxiglucose F18 , Fibrose , Inflamação
7.
Ann Am Thorac Soc ; 20(4): 574-583, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36476449

RESUMO

Rationale: There is upper airway inflammation in patients with obstructive sleep apnea (OSA), which reduces with continuous positive airway pressure (CPAP) therapy. Objectives: Validate the use of positron emission tomography (PET)/magnetic resonance imaging (MRI) to quantify metabolic activity within the pharyngeal mucosa of patients with OSA against nasal lavage proteomics and assess the impact of CPAP therapy. Methods: Adults with OSA underwent [18F]-Fluoro-2-deoxy-D-glucose PET/MRI of the neck before and 3 months after initiating CPAP. Nasal lavage samples were collected. Inflammatory protein expression from samples was analyzed using the Olink platform. Upper airway imaging segmentation was performed. Target-to-background ratio (TBRmax) was calculated from target pharyngeal maximum standard uptake values (SUV) and personalized background mean SUV. Most-diseased segment TBRmax was identified per participant at locations with the highest PET avidity. Correlation analysis was performed between baseline TBRmax and nasal lavage proteomics. TBRmax was compared before and after CPAP using linear mixed-effect models. Results: Among 38 participants, the baseline mean age was 46.3 years (standard deviation [SD], 12.5), 21% were female, the mean body mass index was 30.9 kg/m2 (SD, 4.6), and the mean respiratory disturbance index measured by peripheral arterial tonometry was 31 events/h (SD, 16.4). There was a significant positive correlation between pharyngeal mucosa most-diseased segment TBRmax and nasal lavage proteomic inflammation (r = 0.41 [P < 0.001, false discovery rate = 0.002]). Primary analysis revealed a reduction in the most-diseased segment TBRmax after a median of 2.91 months of CPAP therapy (-0.86 [standard error (SE) ± 0.30; P = 0.007]). Stratified analysis by smoking status revealed a significantly decreased most-diseased segment TBRmax after CPAP therapy among never-smokers but not among ever-smokers (-1.01 [SE ± 0.39; P = 0.015] vs. -0.64 [SE ± 0.49; P = 0.201]). Conclusions: CPAP therapy reduces metabolic activity measured by PET/MRI within the upper airway of adults with OSA. Furthermore, PET/MRI measures of upper airway metabolic activity correlate with a noninvasive marker of inflammation (i.e., nasal lavage inflammatory protein expression).


Assuntos
Proteômica , Apneia Obstrutiva do Sono , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Imageamento por Ressonância Magnética , Inflamação/diagnóstico por imagem , Tomografia por Emissão de Pósitrons
8.
Ann Rheum Dis ; 82(3): 324-330, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36450449

RESUMO

OBJECTIVE: Recent large-scale randomised trials demonstrate that immunomodulators reduce cardiovascular (CV) events among the general population. However, it is uncertain whether these effects apply to rheumatoid arthritis (RA) and if certain treatment strategies in RA reduce CV risk to a greater extent. METHODS: Patients with active RA despite use of methotrexate were randomly assigned to addition of a tumour necrosis factor (TNF) inhibitor (TNFi) or addition of sulfasalazine and hydroxychloroquine (triple therapy) for 24 weeks. Baseline and follow-up 18F-fluorodeoxyglucose-positron emission tomography/CT scans were assessed for change in arterial inflammation, an index of CV risk, measured as an arterial target-to-background ratio (TBR) in the carotid arteries and aorta. RESULTS: 115 patients completed the protocol. The two treatment groups were well balanced with a median age of 58 years, 71% women, 57% seropositive and a baseline disease activity score in 28 joints of 4.8 (IQR 4.0, 5.6). Baseline TBR was similar across the two groups. Significant TBR reductions were observed in both groups-ΔTNFi: -0.24 (SD=0.51), Δtriple therapy: -0.19 (SD=0.51)-without difference between groups (difference in Δs: -0.02, 95% CI -0.19 to 0.15, p=0.79). While disease activity was significantly reduced across both treatment groups, there was no association with change in TBR (ß=0.04, 95% CI -0.03 to 0.10). CONCLUSION: We found that addition of either a TNFi or triple therapy resulted in clinically important improvements in vascular inflammation. However, the addition of a TNFi did not reduce arterial inflammation more than triple therapy. TRIAL REGISTRATION NUMBER: NCT02374021.


Assuntos
Antirreumáticos , Arterite , Artrite Reumatoide , Doenças Cardiovasculares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Antirreumáticos/efeitos adversos , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/induzido quimicamente , Fator de Necrose Tumoral alfa , Fatores de Risco , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/induzido quimicamente , Metotrexato/uso terapêutico , Fatores Imunológicos/uso terapêutico , Fatores de Risco de Doenças Cardíacas , Arterite/induzido quimicamente , Arterite/tratamento farmacológico , Resultado do Tratamento
9.
Radiol Artif Intell ; 4(5): e210315, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36204533

RESUMO

Purpose: To demonstrate the value of pretraining with millions of radiologic images compared with ImageNet photographic images on downstream medical applications when using transfer learning. Materials and Methods: This retrospective study included patients who underwent a radiologic study between 2005 and 2020 at an outpatient imaging facility. Key images and associated labels from the studies were retrospectively extracted from the original study interpretation. These images were used for RadImageNet model training with random weight initiation. The RadImageNet models were compared with ImageNet models using the area under the receiver operating characteristic curve (AUC) for eight classification tasks and using Dice scores for two segmentation problems. Results: The RadImageNet database consists of 1.35 million annotated medical images in 131 872 patients who underwent CT, MRI, and US for musculoskeletal, neurologic, oncologic, gastrointestinal, endocrine, abdominal, and pulmonary pathologic conditions. For transfer learning tasks on small datasets-thyroid nodules (US), breast masses (US), anterior cruciate ligament injuries (MRI), and meniscal tears (MRI)-the RadImageNet models demonstrated a significant advantage (P < .001) to ImageNet models (9.4%, 4.0%, 4.8%, and 4.5% AUC improvements, respectively). For larger datasets-pneumonia (chest radiography), COVID-19 (CT), SARS-CoV-2 (CT), and intracranial hemorrhage (CT)-the RadImageNet models also illustrated improved AUC (P < .001) by 1.9%, 6.1%, 1.7%, and 0.9%, respectively. Additionally, lesion localizations of the RadImageNet models were improved by 64.6% and 16.4% on thyroid and breast US datasets, respectively. Conclusion: RadImageNet pretrained models demonstrated better interpretability compared with ImageNet models, especially for smaller radiologic datasets.Keywords: CT, MR Imaging, US, Head/Neck, Thorax, Brain/Brain Stem, Evidence-based Medicine, Computer Applications-General (Informatics) Supplemental material is available for this article. Published under a CC BY 4.0 license.See also the commentary by Cadrin-Chênevert in this issue.

10.
J Am Coll Cardiol ; 80(8): 832-844, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35981827

RESUMO

Inflammatory aortitis is most often caused by large vessel vasculitis (LVV), including giant cell arteritis, Takayasu's arteritis, immunoglobulin G4-related aortitis, and isolated aortitis. There are distinct differences in the clinical presentation, imaging findings, and natural history of LVV that are important for the cardiovascular provider to know. If possible, histopathologic specimens should be obtained to aide in accurate diagnosis and management of LVV. In most cases, corticosteroids are utilized in the acute phase, with the addition of steroid-sparing agents to achieve disease remission while sparing corticosteroid toxic effects. Endovascular and surgical procedures have been described with success but should be delayed until disease control is achieved whenever possible. Long-term management should include regular follow-up with rheumatology and surveillance imaging for sequelae of LVV.


Assuntos
Aortite , Arterite de Células Gigantes , Arterite de Takayasu , Aorta/patologia , Aortite/diagnóstico por imagem , Aortite/terapia , Arterite de Células Gigantes/diagnóstico , Arterite de Células Gigantes/tratamento farmacológico , Humanos , Imunoglobulina G , Arterite de Takayasu/diagnóstico , Arterite de Takayasu/patologia , Arterite de Takayasu/terapia
11.
J Nucl Cardiol ; 29(4): 1660-1670, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34046803

RESUMO

Non-invasive positron emission tomography (PET) of vascular inflammation and atherosclerotic plaque by identifying increased uptake of 18F-fluordeoxyglucose (18F-FDG) is a powerful tool for monitoring disease activity, progression, and its response to therapy. 18F-FDG PET/computed tomography (PET/CT) of the aorta and carotid arteries has become widely used to assess changes in inflammation in clinical trials. However, the recent advent of hybrid PET/magnetic resonance (PET/MR) scanners has advantages for vascular imaging due to the reduction in radiation exposure and improved soft tissue contrast of MR compared to CT. Important for research and clinical use is an understanding of the scan-rescan repeatability of the PET measurement. While this has been studied for PET/CT, no data is currently available for vascular PET/MR imaging. In this study, we determined the scan-rescan measurement repeatability of 18F-FDG PET/MR in the aorta and carotid arteries was less than 5%, comparable to similar findings for 18F-FDG PET/CT.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Inflamação/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
12.
JACC Cardiovasc Imaging ; 15(1): 108-120, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34274283

RESUMO

OBJECTIVES: This study investigated whether pulmonary artery (PA) 18F-FDG uptake is associated with hypertension, and if it correlates to elevated pulmonary pressures. BACKGROUND: 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with computed tomography or cardiac magnetic resonance (CMR) has been used to assess inflammation mostly in large arteries of the systemic circulation. Much less is known about inflammation of the vasculature of the pulmonary system and its relationship to pulmonary hypertension (PH). METHODS: In a single-center cohort of 175 patients with suspected cardiac sarcoidosis, who underwent hybrid thoracic PET/CMR, 18F-FDG uptake in the PA was quantified according to maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR) and compared with available results from right heart catheterization (RHC) or transthoracic echocardiography (TTE). RESULTS: Thirty-three subjects demonstrated clear 18F-FDG uptake in the PA wall. In the subgroup of patients who underwent RHC (n = 10), the mean PA pressure was significantly higher in the group with PA 18F-FDG uptake compared with the group without uptake (34.4 ± 7.2 mm Hg vs 25.6 ± 9.3 mm Hg; P = 0.003), and 9 (90%) patients with PA 18F-FDG uptake had PH when a mean PA pressure cutoff of 25 mm Hg was used compared with 18 (45%) in the nonuptake group (P < 0.05). In the subgroup that underwent TTE, signs of PH were present in a significantly higher number of patients with PA 18F-FDG uptake (14 [51.9%] vs 37 [29.8%]; P < 0.05). Qualitative assessment of 18F-FDG uptake in the PA wall showed a sensitivity of 33% and specificity of 96% for separating patients with PH based on RHC-derived PA pressures. SUVmax and TBR in the PA wall correlated with PA pressure derived from RHC and/or TTE. CONCLUSIONS: We demonstrate that 18F-FDG uptake by PET/CMR in the PA is associated with PH and that its intensity correlates with PA pressure.


Assuntos
Hipertensão Pulmonar , Sarcoidose , Fluordesoxiglucose F18 , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Espectroscopia de Ressonância Magnética , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Artéria Pulmonar , Compostos Radiofarmacêuticos , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Sarcoidose/patologia
13.
Sci Rep ; 11(1): 23034, 2021 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-34845314

RESUMO

In recent years, new human magnetic resonance imaging systems operating at static magnetic fields strengths of 7 Tesla or higher have become available, providing better signal sensitivity compared with lower field strengths. However, imaging human-sized objects at such high field strength and associated precession frequencies is limited due to the technical challenges associated with the wavelength effect, which substantially disturb the transmit field uniformity over the human body when conventional coils are used. Here we report a novel passive inductively-coupled radiofrequency resonator array design with a simple structure that works in conjunction with conventional coils and requires only to be tuned to the scanner's operating frequency. We show that inductive-coupling between the resonator array and the coil improves the transmit efficiency and signal sensitivity in the targeted region. The simple structure, flexibility, and cost-efficiency make the proposed array design an attractive approach for altering the transmit field distribution specially at high field systems, where the wavelength is comparable with the tissue size.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Adulto , Engenharia Biomédica , Simulação por Computador , Meios de Contraste , Eletricidade , Radiação Eletromagnética , Desenho de Equipamento , Feminino , Temperatura Alta , Humanos , Campos Magnéticos , Magnetismo , Masculino , Pessoa de Meia-Idade , Nanotecnologia , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
15.
Sci Adv ; 7(10)2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33674313

RESUMO

Immunotherapies controlling the adaptive immune system are firmly established, but regulating the innate immune system remains much less explored. The intrinsic interactions between nanoparticles and phagocytic myeloid cells make these materials especially suited for engaging the innate immune system. However, developing nanotherapeutics is an elaborate process. Here, we demonstrate a modular approach that facilitates efficiently incorporating a broad variety of drugs in a nanobiologic platform. Using a microfluidic formulation strategy, we produced apolipoprotein A1-based nanobiologics with favorable innate immune system-engaging properties as evaluated by in vivo screening. Subsequently, rapamycin and three small-molecule inhibitors were derivatized with lipophilic promoieties, ensuring their seamless incorporation and efficient retention in nanobiologics. A short regimen of intravenously administered rapamycin-loaded nanobiologics (mTORi-NBs) significantly prolonged allograft survival in a heart transplantation mouse model. Last, we studied mTORi-NB biodistribution in nonhuman primates by PET/MR imaging and evaluated its safety, paving the way for clinical translation.


Assuntos
Sistema Imunitário , Nanopartículas , Animais , Imunoterapia , Camundongos , Sirolimo/farmacologia , Distribuição Tecidual
16.
J Nucl Cardiol ; 28(5): 1-12, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31792913

RESUMO

BACKGROUND: 18F-Fluoride uptake denotes calcification activity in aortic stenosis and atherosclerosis. While PET/MR has several advantages over PET/CT, attenuation correction of PET/MR data is challenging, limiting cardiovascular application. We compared PET/MR and PET/CT assessments of 18F-fluoride uptake in the aortic valve and coronary arteries. METHODS AND RESULTS: 18 patients with aortic stenosis or recent myocardial infarction underwent 18F-fluoride PET/CT followed immediately by PET/MR. Valve and coronary 18F-fluoride uptake were evaluated independently. Both standard (Dixon) and novel radial GRE) MR attenuation correction (AC) maps were validated against PET/CT with results expressed as tissue-to-background ratios (TBRs). Visually, aortic valve 18F-fluoride uptake was similar on PET/CT and PET/MR. TBRMAX values were comparable with radial GRE AC (PET/CT 1.55±0.33 vs. PET/MR 1.58 ± 0.34, P = 0.66; 95% limits of agreement - 27% to + 25%) but performed less well with Dixon AC (1.38 ± 0.44, P = 0.06; bias (-)14%; 95% limits of agreement - 25% to + 53%). In native coronaries, 18F-fluoride uptake was similar on PET/MR to PET/CT regardless of AC approach. PET/MR identified 28/29 plaques identified on PET/CT; however, stents caused artifact on PET/MR making assessment of 18F-fluoride uptake challenging. CONCLUSION: Cardiovascular PET/MR demonstrates good visual and quantitative agreement with PET/CT. However, PET/MR is hampered by stent-related artifacts currently limiting clinical application.


Assuntos
Fluordesoxiglucose F18/uso terapêutico , Angiografia por Ressonância Magnética/normas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18/administração & dosagem , Humanos , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico
17.
J Nucl Cardiol ; 28(5): 2194-2204, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31898004

RESUMO

BACKGROUND: Hybrid PET/MR imaging has significant potential in cardiology due to its combination of molecular PET imaging and cardiac MR. Multi-tissue-class MR-based attenuation correction (MRAC) is necessary for accurate PET quantification. Moreover, for thoracic PET imaging, respiration is known to lead to misalignments of MRAC and PET data that result in PET artifacts. These factors can be addressed by using multi-echo MR for tissue segmentation and motion-robust or motion-gated acquisitions. However, the combination of these strategies is not routinely available and can be prone to errors. In this study, we examine the qualitative and quantitative impacts of multi-class MRAC compared to a more widely available simple two-class MRAC for cardiac PET/MR. METHODS AND RESULTS: In a cohort of patients with cardiac sarcoidosis, we acquired MRAC data using multi-echo radial gradient-echo MR imaging. Water-fat separation was used to produce attenuation maps with up to 4 tissue classes including water-based soft tissue, fat, lung, and background air. Simultaneously acquired 18F-fluorodeoxyglucose PET data were subsequently reconstructed using each attenuation map separately. PET uptake values were measured in the myocardium and compared between different PET images. The inclusion of lung and subcutaneous fat in the MRAC maps significantly affected the quantification of 18F-fluorodeoxyglucose activity in the myocardium but only moderately altered the appearance of the PET image without introduction of image artifacts. CONCLUSION: Optimal MRAC for cardiac PET/MR applications should include segmentation of all tissues in combination with compensation for the respiratory-related motion of the heart. Simple two-class MRAC is adequate for qualitative clinical assessment.


Assuntos
Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/normas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Idoso , Estudos de Coortes , Feminino , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Coração/fisiopatologia , Humanos , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico
18.
Radiology ; 298(2): 332-340, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33258745

RESUMO

Background Tumor perfusion may inform therapeutic response and resistance in metastatic renal cell carcinoma (RCC) treated with antiangiogenic therapy. Purpose To determine if arterial spin labeled (ASL) MRI perfusion changes are associated with tumor response and disease progression in metastatic RCC treated with vascular endothelial growth factor receptor (VEGFR) tyrosine kinase inhibitors (TKIs). Materials and Methods In this prospective study (ClinicalTrials.gov identifier: NCT00749320), metastatic RCC perfusion was measured with ASL MRI before and during sunitinib or pazopanib therapy between October 2008 and March 2014. Objective response rate (ORR) and progression-free survival (PFS) were calculated. Perfusion was compared between responders and nonresponders at baseline, at week 2, after cycle 2 (12 weeks), after cycle 4 (24 weeks), and at disease progression and compared with the ORR by using the Wilcoxon rank sum test and with PFS by using the log-rank test. Results Seventeen participants received sunitinib (mean age, 59 years ± 7.0 [standard deviation]; 11 men); 11 participants received pazopanib (mean age, 63 years ± 6.6; eight men). Responders had higher baseline tumor perfusion than nonresponders (mean, 404 mL/100 g/min ± 213 vs 199 mL/100 g/min ± 136; P = .02). Perfusion decreased from baseline to week 2 (-53 mL/100 g/min ± 31; P < .001), after cycle 2 (-65 mL/100 g/min ± 25; P < .001), and after cycle 4 (-79 mL/100 g/min ± 15; P = .008). Interval reduction in perfusion at those three time points was not associated with ORR (P = .63, .29, and .27, respectively) or PFS (P = .28, .27, and .32). Perfusion increased from cycle 4 to disease progression (51% ± 11; P < .001). Conclusion Arterial spin labeled perfusion MRI may assist in identifying responders to vascular endothelial growth factor receptor tyrosine kinase inhibitors and may help detect early evidence of disease progression in patients with metastatic renal cell carcinoma. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Goh and De Vita in this issue.


Assuntos
Carcinoma de Células Renais/tratamento farmacológico , Neoplasias Renais/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Inibidores de Proteínas Quinases/uso terapêutico , Pirimidinas/uso terapêutico , Sulfonamidas/uso terapêutico , Sunitinibe/uso terapêutico , Adulto , Idoso , Carcinoma de Células Renais/secundário , Feminino , Humanos , Indazóis , Neoplasias Renais/secundário , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Proteínas Tirosina Quinases/antagonistas & inibidores , Marcadores de Spin
19.
PLoS One ; 15(12): e0241779, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33315867

RESUMO

Accurate quantification and characterization of atherosclerotic plaques with MRI requires high spatial resolution acquisitions with excellent image quality. The intrinsically better signal-to-noise ratio (SNR) at high-field clinical 7T compared to the widely employed lower field strengths of 1.5 and 3T may yield significant improvements to vascular MRI. However, 7T atherosclerosis imaging also presents specific challenges, related to local transmit coils and B1 field inhomogeneities, which may overshadow these theoretical gains. We present the development and evaluation of 3D, black-blood, ultra-high resolution vascular MRI on clinical high-field 7T in comparison lower-field 3T. These protocols were applied for in vivo imaging of atherosclerotic rabbits, which are often used for development, testing, and validation of translatable cardiovascular MR protocols. Eight atherosclerotic New Zealand White rabbits were imaged on clinical 7T and 3T MRI scanners using 3D, isotropic, high (0.63 mm3) and ultra-high (0.43 mm3) spatial resolution, black-blood MR sequences with extensive spatial coverage. Following imaging, rabbits were sacrificed for validation using fluorescence imaging and histology. Image quality parameters such as SNR and contrast-to-noise ratio (CNR), as well as morphological and functional plaque measurements (plaque area and permeability) were evaluated at both field strengths. Using the same or comparable imaging parameters, SNR and CNR were in general higher at 7T compared to 3T, with a median (interquartiles) SNR gain of +40.3 (35.3-80.1)%, and a median CNR gain of +68.1 (38.5-95.2)%. Morphological and functional parameters, such as vessel wall area and permeability, were reliably acquired at 7T and correlated significantly with corresponding, widely validated 3T vessel wall MRI measurements. In conclusion, we successfully developed 3D, black-blood, ultra-high spatial resolution vessel wall MRI protocols on a 7T clinical scanner. 7T imaging was in general superior to 3T with respect to image quality, and comparable in terms of plaque area and permeability measurements.


Assuntos
Aterosclerose/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/lesões , Aorta Abdominal/patologia , Aterosclerose/etiologia , Aterosclerose/patologia , Dieta Hiperlipídica/efeitos adversos , Modelos Animais de Doenças , Estudos de Viabilidade , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/patologia , Coelhos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
20.
Circ Cardiovasc Imaging ; 13(10): e010586, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33076700

RESUMO

BACKGROUND: Macrophages, innate immune cells that reside in all organs, defend the host against infection and injury. In the heart and vasculature, inflammatory macrophages also enhance tissue damage and propel cardiovascular diseases. METHODS: We here use in vivo positron emission tomography (PET) imaging, flow cytometry, and confocal microscopy to evaluate quantitative noninvasive assessment of cardiac, arterial, and pulmonary macrophages using the nanotracer 64Cu-Macrin-a 20-nm spherical dextran nanoparticle assembled from nontoxic polyglucose. RESULTS: PET imaging using 64Cu-Macrin faithfully reported accumulation of macrophages in the heart and lung of mice with myocardial infarction, sepsis, or pneumonia. Flow cytometry and confocal microscopy detected the near-infrared fluorescent version of the nanoparticle (VT680Macrin) primarily in tissue macrophages. In 5-day-old mice, 64Cu-Macrin PET imaging quantified physiologically more numerous cardiac macrophages. Upon intravenous administration of 64Cu-Macrin in rabbits and pigs, we detected heightened macrophage numbers in the infarcted myocardium, inflamed lung regions, and atherosclerotic plaques using a clinical PET/magnetic resonance imaging scanner. Toxicity studies in rats and human dosimetry estimates suggest that 64Cu-Macrin is safe for use in humans. CONCLUSIONS: Taken together, these results indicate 64Cu-Macrin could serve as a facile PET nanotracer to survey spatiotemporal macrophage dynamics during various physiological and pathological conditions. 64Cu-Macrin PET imaging could stage inflammatory cardiovascular disease activity, assist disease management, and serve as an imaging biomarker for emerging macrophage-targeted therapeutics.


Assuntos
Radioisótopos de Cobre , Dextranos , Coração/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Macrófagos/patologia , Imagem Molecular , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Animais , Aterosclerose/diagnóstico por imagem , Aterosclerose/patologia , Radioisótopos de Cobre/administração & dosagem , Radioisótopos de Cobre/farmacocinética , Dextranos/administração & dosagem , Dextranos/farmacocinética , Modelos Animais de Doenças , Injeções Intravenosas , Pulmão/patologia , Macrófagos Alveolares/patologia , Camundongos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Nanopartículas , Pneumonia/diagnóstico por imagem , Pneumonia/patologia , Valor Preditivo dos Testes , Coelhos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Suínos , Porco Miniatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA